1. National Fire Agency. The Status of the Dispatch by Fire and Misunderstanding in the Dispatch of 119 Service since 2014, (2019).
2. S. H. Sakong, “False Fire Alarm of Automatic Fire Detection System”, Korea Fire Institute (KFI), Fire Safety, Vol. 22, pp. 3-41 (1985).
3. J. S. Cho, “A Study about Reduction Measures of False Fire Alarms in Automatic Fire Detection System”, Master’s Thesis, Yonsei University, (1986).
4. E. Y. Yeol, Investigation Research - False Fire Alarms Status and Measures of Automatic Fire Detection System, Korea Fire Protection Associate (KFPA), Fire Protection Technology, No. 4, pp. 22-32 (1988).
5. M. H. Choi, “A Review about the Unwanted Fire Alarm and False Alarm of Automatic Fire Detection System”, Journal of Korean Institute of Fire Science & Engineering, Vol. 4, No. 2, pp. 45-56 (1990).
6. J. H. Kim and H. K. Lim, “Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms”, Journal of The Korea Society of Safety, Vol. 8, No. 1, pp. 6-17 (1993).
7. M.G. Kim, “A Study on Improving the False Alarm Problems of Fire Detection Systems”, Master’s Thesis, Kyungsung University, (1994).
8. C. O. Son, “A Study on Preventing the Malfunction of Automatic Fire Detection Equipments”, Master’s Thesis, Dongguk University, (1997).
9. S. W. Nam, “The Improvement Measures about Reliability and False Fire Alarm of Automatic Fire Detection System”, National Fire Service Academy (NFSA), Fire Research Journal, Vol. 10, (2000).
10. Y. J. Ahn, “A Study on the Reduction of Nuisance Alarms for the Photoelectric Addressable Analog Smoke Detector - Case Study on Hospital”, Master’s Thesis, Seoul National University of Technology, (2002).
11. G. T. Jung, “A Study on Design of a Fire Smoke Detector with Auto-uning Sensitivity for Prevention of False Alarm”, Master’s Thesis, University of Seoul, (2004).
12. T. D. Kim, “A Study on the Improvement of False Fire Alarm in Auto Fire Detect System”, Master’s Thesis, University of Seoul, (2005).
13. J. M. Lee, “A Study on the False Fire Alarm of Computational Center”, Master’s Thesis, Kyungwon University, (2010).
14. J. H. Lee, C. H. Lee, S. K. Kim and H. S. Kong, “A Study about False Alarm of Automatic Fire Detection System”, Journal of the Korea Safety Management & Science, Vol. 13, No. 1, pp. 41-49 (2011).
15. K. J. Lee, H. G. Kim, B. W. Lee, T. O. Kim and D. I. Shin, “Test Bed Design of Fire Detection System Based on Multi-Sensor Information for Reduction of False Alarms”, Journal of the Korean Institute of Gas, Vol. 16, No. 6, pp. 107-114 (2012).
16. Y. C. Lee, “A Research about the Wireless Combinational Single Detector to Prevent Unwanted Alarm”, Master’s Thesis, University of Seoul, (2012).
17. Korea Fire Institute. “About Unwanted Fire Alarm of Automated Fire Detection System”, KFI Report, (2013).
18. Korea Fire Institute. Technical Suggestions to reduce Unwanted Fire Alarms in Automated Fire Detection System, KFI Report (2015).
19. J. H. Cha, “A Study on Improving the Standard Related to Fire Alarm Malfunction in Security System”, Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology (AJMAHS), Vol. 6, No. 12, pp. 675-682 (2016).
20. B. K. Seo and S. G. Nam, “Study of the Improvement of False Fire Alarms in Analog Photoelectric Type Smoke Detectors”, Fire Science and Engineering, Vol. 30, No. 5, pp. 108-115 (2016).
21. S. S. Lee, “A Study on Improvement of the Smoke Detector for Unwanted Alarm in Korea”, Master’s Thesis, Mokwon University, (2016).
22. T. W. Kim, “A Study on the Improvement of Fire Alarm System”, Master’s Thesis, Kyonggi University, (2018).
23. S. O. Na, “An Analysis of Occurrence Frequency of False Fire Alarms on Specific Objects Targeted for Fire Prevention Law Focused on Seocheon-gun”, Master’s Thesis, Kongju University, (2019).
24. National Fire Ageny and Korea Fire Institute. To Reduce Unwanted Fire Alarms-Adaptation Sensor Selection and Management Reference by Location, (2019).
25. U.S. National Bureau of Srandards Washington D.C.“NBS GCR 75-51_Detector Sensitivity and Siting Requirememts for Dwellings”, Technical Report, (1975).
26. U.S. National Bureau of Srandards Washington D.C.“NBS GCR 77-82_Detector Sensitivity and Siting Requirememts for Dwellings 2”, Technical Report, (1977).
27. J. A. Milke and T. J. Mcavoy, Analysis of Fire and Non-fire Signatures for Discriming Fire Detection, Fire Safety Science-Proceedings of the Fifth International Symposium, pp. 819-828 (1997).
28. D. T. Gottuk, M. J. Peatross, R. J. Roby and C. L. Beyler, “Advanced Fire Detection Using Multi-signature Alarm Algorithms”, Fire Safety Jounal, Vol. 37, pp. 381-394 (2002).
29. Public/Private Fire Safety Council. “Home Smoke Alarms”, White Paper, (2006).
30. Fire Protection Research Foundation. “Smoke Characterization Project”, FPRF Techincal Report, (2007).
31. National Institute of Standards and Technology. “Performance of Home Smoke Alarms Analysis of the Response of Several Available Technologies in Residential Fire Settings”, NIST Technical Note 1455-1, (2008).
32. International Fire Chief Association. Position Statement - Eliminating Unwanted and Nuisance Fire Alarm Activations, (2009).
33. T. G. Cleary, “Results from a Full-Scale Smoke Alarm Sensitivity Study”, Suppression and Presented at the Fire Protection Research Foundation’s 13th Annual Detection Research and Applications Symposium, (2009).
34. U.S. Consumer Product Safety Commission. Smoke Alarms - Pilot Study of Nuisance Alarms Associated with Cooking, (2010).
35. National Fire Protection Associate. Unwanted Fire Alarm, (2011).
36. Underwriters Laboratories Inc. “Smoke Alarms and the Modern Residence Fire”, Recent Studies and Reserach at UL, pp 1-9, (2011).
37. National Fire Protection Associate. “Fire Service Guide to Reducing Unwanted Fire Alarms”, NFPA Guideline, (2012).
38. W. E. Barnard, “Maryland Smoke Alarm Technology Task Force”, Final Report, (2012).
39. National Institute of Standards and Technology. “Smoke Alarm Performance in Kitchen Fires and Nuisance Alarm Scenarios”, NIST Technical Note 1784, (2013).
40. Fire Protection Research Foundation. “Development of a Risk-Based Decision Support Tool to Assist Fire Departments in Managing Unwanted Alarms”, FPRF Final Report, (2013).
41. National Institute of Standards and Technology. “Improving Smoke Alarm Performance - Justification for New Smoldering and Flaming Test Performance Criteria”, NIST Technial Note 1837, (2014).
42. Fire Protection Research Foundation. “Smoke Alarm Nuisance Source Characterization: Experimental Results”, FPRF Final Report, (2015).
43. Underwriters Laboratories Inc. “Characterization of Smoke Alarm Nuisance Sources from Cooking Scenarios”, UL Research Report, (2015).
44. R. E. Zevotek, “Identification of Precurser Signals to Impeding Cooking Related Fires”, Master’s Thesis, University of Maryland, (2015).
45. National Institute of Standards and Technology. “A Study on the Performance of Current Smoke Alarms to the New Fire and Nuisance Tests Prescribed in ANSI/UL 217-2015”, NIST Technial Note 1947, (2016).
46. National Fire Protection Associate. “What’s Going on with Unwanted Alarms?” NFPA Research Report, (2016).
47. S. Festag and L. Rutimann, “False Alarms of Fire Detection and Fire Alarm Systems in Selected European Countries”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
48. E. Johnson and M. Zarzecki, “Using Smoke Obscuration to Warn of Pre-Ignition Conditions of Unattended Cooking Fires”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
49. W. Makant, “Smoke Plus Infra-red Sensors as an Alternative Fire Detection for Activation of a Residential Fire Suppression Appliance”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
50. E. Ren, N. Zalmai, H. A. Loeliger and M. Stager, “Multichannel Information Processing for Fire Detection”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
51. R. Roberts, “NFPA 72, Chapter 29 Nuisance Alarm Requirements”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
52. R. Zheng, Y. Cheng, S. Lu and H. Zhang, “A Study on Scattering Characterization of Water Steam Aerosols for Smoke Detector”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
53. B. Stockbroeckx, “Wireless Interconnections in Fire Detection and Fire Alarm Systems: Points of Attention for the Installer and the Belgian Application Standard”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
54. Office of the Deputy Prime Minister. “A Guide to Reducing the Number of False Alarms from Fire-detection and Fire-alarm Systems”, Booklet, (2004).
55. Northern Ireland Fire & Rescue Service. “False Alarm & Unwanted Fire Signal Poilcy”, NIFRS Community Development Department (2013).
56. Building Research Establishment Ltd. The Causes of False Fire Alarms in Buildings, BRE Global Briefing Paper 2014..
57. Chief Fire Officers’ Association. “CFOA Guidance for the Reduction of False Alarms & Unwanted Fire Signals”, CFOA Publications (2014).
58. L. Rutimann, “Reducing False Fire Alams - A Study of Selected European Countries”, Euralarm, (2014).
59. Llywodraeth Cymru Welsh Government. Time for Action, A Report Exploring the Impact of False Alarms in Wales 2015..
60. S. Festag and L. Rutimann, “False Alarms of Fire Detection and Fire Alarm Systems in selected European Countries”, The 2017 Suppression, Detection, and Signaling Research and Applications Conference (SUPDET 2017) & the 16th International Conference on Fire Detection (AUBE ‘17), (2017).
61. Building Research Establishment Ltd. “Live Investigations of False Fire Alarms”, BRE Global Briefing Paper, (2018).
62. Building Research Establishment Ltd. “The Performance of Multi-Sensors in Fire and False Alarm Tests”, BRE Global Briefing Paper, (2018).
63. Fire Protection Association. “Automatic Fire Alarm & Detection Systems”, ABI Work Programme - Worksteam Two Final, (2018).
64. Northern Ireland Fire & Rescue Service. Reducing Unwanted Fire Signals, (2019).
65. Goverment U.K.Home Office - The Regulatory Reform (Fire Safety) Order 2005 - Call for Evidence, (2019).
66. National Fire Agency. National Fire Data System, (2014-2018).
67. National Fire Agency. Fire department on-site unwanted alarm inspection checklist(complete analysis data), (2018).
68. National Fire Data Center. “National Fire Incident Reporting System”, Complete Reference Guide, (2015).
69. National Fire Protetion Associate. Fire Loss in the United States During 2014, (2015).
70. National Fire Protetion Associate. Fire Loss in the United States During 2015, (2016).
71. National Fire Protetion Associate. Fire Loss in the United States During 2016, (2017).
72. National Fire Protetion Associate. Fire Loss in the United States During 2017, (2018).
73. National Fire Protetion Associate. Fire Loss in the United States During 2018, (2019).
74. Department for Communities and Local Government: London. “Incident Recording System - Questions and Lists”, Version 1.6, (2012).
75. U.K. Goverment, Home Office (2018e), Fire Statistics Table 0104: Fire false alarm by reason for false alarm, England, (2019).
76. U.K. Goverment, Home Office (2018e) Fire Statistics Table 0901: Non-fire incidents attended, by types of incident and fire and rescue authority, England, (2019).
77. Scottish Fire and Rescue Service. Fire and Rescue Incident Statistic - Table and Charts Scottish Fire and Rescue Service, (2019).
78. Stats Wales. False alarms by reason and financial year, (2019).
79. Northern Ireland Fire and Rescue Service. Table 3. False Alarm Calls received by NIFRS, (2015).