Fire Science and Engineering 2019;33(6):53-62.
DOI: https://doi.org/10.7731/KIFSE.2019.33.6.053    Published online December 31, 2019.
CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구
김미선1, 서동길1, 구선환2, 유영민3, 송영주4
1에이원 소방 이사
2에이원 소방 연구원
3에이원 소방 소장
4동신대학교 소방행정학과 교수
Smoke Control Performance of a Serial Structure Using “CONTAM”
Mi-Seon Kim1, ⋅Dong-Gil Seo1, Seon-Hwan Gu2, Young-Min Yoo3, Young-Joo Song4
1Director, A-ONE Fire Protection
2Researcher, A-ONE Fire Protection
3Chief Executive Officer, A-ONE Fire Protection
4Professor, Dept. of Fire Administration, Dongshin Univ
Correspondence:  Young-Joo Song, Tel: +82-61-330-3563, Fax: +82-61-330-3568, 
Email: dewangel1@naver.com
Received: 11 November 2019   • Revised: 20 November 2019   • Accepted: 25 November 2019
요약
최근 건축물은 대지 이용의 효율성을 높이기 위해 주상 복합화․고층화되는 추세이며, 이에 따른 화재의 발생빈도 및 잠재적인 위험요소도 증가하고 있다. 특히, 고층 공동주택의 경우 비상용승강기와 별도로 승용승강기 중 1대 이상을 피난용승강기로 설치하게 되어 특별피난계단 부속실, 비상용승강기 승강장 겸용의 경우 피난용승강기 승강장과 직렬형태의 구조가 되어 새로운 형태의 제연구역 이 발생한다. 따라서 비상용승강기 승강장과 피난용승강기 승강장의 직렬형태 구조에 대한 제연구역 선정의 제시가 필요하며, 새로운 형태에서 제연성능을 달성하는 것에 대한 문제가 대두되고 있다. 따라서 본 논문에서는 이러한 문제를 해결하기 위해 CONTAM을 이용하여 각 제연구역 형식(비상용승강기 승강장 단독제연, 피난용승강기 승강장 단독제연, 비상용승강기 승강장과 피난용승강기 승강장 동시제연 누설틈새 적용· 미적용)의 방연풍속, 차압을 확인하고, 직렬형태 구조에 대해 제연성능을 확보하기 위한 방안을 제시하고자 한다.
Abstract
A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.
Key Words: CONTAM, Serial structure, Air egress velocity, Differential pressure


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
22, Teheran-ro 7-gil, Gangnam-gu, Seoul 06130, Republic of Korea
Tel: +82-2-555-2450    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2020 by Korean Institute of Fire Science and Engineering. All rights reserved.

Developed in M2community

Close layer
prev next