A Study on Fire Hazard by Metallic Migration
Gyeong Won Choi1, Byoung Soo Hyun1, Sun Jae Kim1, Kyu Young Lim1, Seung Woo Woo1, Dong Kyu Lee1, Young Jin Cho2, Jong Taek Park2, Jae Mo Goh3, Nam Kyu Park4
1Researcher, National Forensic Service
2Team Leader, National Forensic Service
3Director, National Forensic Service
4President, National Forensic Service
Correspondence:  Gyeong Won Choi, Tel: +82-33-902-5556, Fax: +82-33-902-5934, 
Email: kkc7030@korea.kr
Received: 22 October 2019   • Revised: 5 November 2019   • Accepted: 5 November 2019
요약
우리는 LED등기구의 Printed circuit board (PCB)에서 화재의 원인으로 특정할 수 있는 금속 마이그레이션(Metallic migration) 현상을 발견하고, 본 연구를 진행하였다. 금속 마이그레이션 현상 가속화 실험인 물방울 시험을 소량의 물과 저전압(3 V)로 진행하고 절연되어있는 양극에서 직접적으로 금속 마이그레이션의 성장과 회로의 단락을 확인하였다. 그리고 전자주사현미경(SEM)을 통해 형태를 관찰하고 에너지 분산형 분광기(EDS)를 이용하여 성분을 분석한 결과, 절연된 부분에서 전극을 이루고 있는 구리의 성분을 검출하였다.
Abstract
We found metallic migration phenomena at the fire scene in Printed circuit board (PCB) of LED light equipment which are commonly used. Accordingly we did this study. In order to generate rapidly metallic migration, we experiment the water drop test under low voltage (3.0 V) and a small amount of water condition. As a results of our experiment, we saw the growth of metallic migration of Copper and checked directly short of the PCB between isolated two poles by Cu migration. Finally we saw the shape of dendrite pattern by Cu migration using Scanning electron microscope (SEM) and analyzed that components via Energy dispersive Spectrometer (EDS).
Key Words: Metallic migration, Ion migration, Insulation degradation, Fire safety, Fire science


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
22, Teheran-ro 7-gil, Gangnam-gu, Seoul 06130, Republic of Korea
Tel: +82-2-555-2450    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2020 by Korean Institute of Fire Science and Engineering. All rights reserved.

Developed in M2community

Close layer
prev next