Fire Sci. Eng. Search

CLOSE


Fire Sci. Eng. > Volume 33(6); 2019 > Article
Fire Science and Engineering 2019;33(6):152-158.
DOI: https://doi.org/10.7731/KIFSE.2019.33.6.152    Published online December 31, 2019.
한국의료패널을 이용한 구급 이송 서비스 이용 특성 분석: 임신, 출산, 산후기 여성을 중심으로
강경희
가천대학교 응급구조학과 교수
Analysis of the Use of Ambulance Services Among Pregnant, Childbearing, and Postpartum Women Using Data from the Korea Health Panel
Kyunghee Kang
Professor, Department of Emergency Health Services, Gachon Univ.
Correspondence:  Kyunghee Kang, Tel: +82-32-820-4345, Fax: +82-32-820-4340, 
Email: khkang@gachon.ac.kr
Received: 23 September 2019   • Revised: 17 October 2019   • Accepted: 22 October 2019
요약
본 연구에서는 한국보건사회연구원과 국민건강보험공단의 한국의료패널 2008-2016년 연간 데이터(Version 1.5)를 이용해 임신, 출산, 산후기 여성의 구급 이송 서비스 이용 특성을 분석하였다. 분석 결과를 요약하면, 첫째, 임신, 출산 및 산후기 여성의 119 구급차, 민간 구급차 등 구급 이송 서비스 이용률은 12.0%로 전체 구급 이송 서비스 이용률 18.9%보다 상대적으로 낮았다. 둘째, 임신, 출산 및 산후기 여성의 응급에서 분만이 38.7%로 가장 큰 비중을 차지하였으며, 진통 및 분만의 합병증이 20.0%, 유산된 임신이 17.3% 등의 순으로 나타났다. 셋째, 임신, 출산 및 산후기 여성의 구급 이송 서비스 이용 특성 중 연 평균 가구소득, 응급실 도착 소요시간, 응급실 도착 지연 인식 등에서 구급이송 서비스의 이용자 집단과 비이용자 집단 사이에 통계적으로 유의한 차이가 나타났다. 따라서 저출산과 고령 산모로 인하여 분만 취약지가 늘어날수록 임신, 출산, 산후기 여성을 위한 사회안전망으로서 구급 이송 서비스의 양적 확대와 질적 제고는 더욱 시급한 과제가 될 것이다.
Abstract
This study examined the socio-economic and clinical characteristics associated with the use of ambulance services among pregnant, childbearing, and postpartum women based on data from the 2008-2016 Korea Health Panel. The analysis revealed that among the pregnant, childbearing, and postpartum women, the proportion using all ambulance services was 18.9% whereas 12.0% used private and 119 ambulances. Moreover, among those using ambulance services, delivery was the most common reason (38.7%) followed by complications of labor and delivery (20.0%) and pregnancy with abortive outcome (17.3%). There were statistically significant differences between the users and non-users of ambulance services in terms of the average annual household income, emergency arrival time, and delayed arrival at the emergency room. As childbirth becomes more complicated due to low fertility and elderly mothers, the expansion and improvement of ambulance services as a social safety net for pregnant, childbearing, and postpartum women will become increasingly important.
Key Words: Ambulance service: Pregnancy, Childbearing and postpartum women, Emergency medical system: Emergency room
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 56 View
  • 2 Download
Related articles in Fire Sci. Eng.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
22, Teheran-ro 7-gil, Gangnam-gu, Seoul 06130, Republic of Korea
Tel: +82-2-555-2450    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2020 by Korean Institute of Fire Science and Engineering. All rights reserved.

Developed in M2community

Close layer
prev next