Journal of Korean Institute of Fire Science and Engineering 2013;27(1):20-25.
DOI: https://doi.org/10.7731/KIFSE.2013.27.1.020    Published online February 28, 2013.
제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석
유우준, 고권현, 사공성호, 남준석, 유홍선
1중앙대학교
2동양대학교
3한국소방산업기술원
4한국소방산업기술원
5중앙대학교
An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone
You Woo Jun, Ko Gwon Hyun, SaKong Seong Ho, Nam Jun-Seok, Ryou Hong-Sun
1Dept. of Mechanical Engineering, Chung-Ang University
2Dept. of Architecture & Fire Administration, Dongyang University
3Korea Fire Institute of Industrial & Technology
4Korea Fire Institute of Industrial & Technology
5Dept. of Mechanical Engineering, Chung-Ang University
요약
본 연구에서 부속실 단독 가압 구조인 급기가압 제연설비의 성능 확보에 영향을 주는 주요 매개 변수를 분석하고 공급유량과 누설면적 변화에 따라서 풍도와 부속실 차압 형성 관계를 실험적으로 분석하였다. 이를 위해서 3층 규모의 총 10개의 구획공간으로 구성된 모형 구조물과 방화문의 개폐력 측정장치를 제작하였으며, 각 구획공간과 외기의 차압, 방연풍속을 측정하기 위한 제어 계측 장비를 구성하였다. 그 결과 댐퍼의 차압조절 범위가 45 Pa~55 Pa인 경우 공급유량과 부속실 차압 크기에 따라서 45 Pa 이하인 저압 영역, 45 Pa~55 Pa 구간인 차압조절 영역 그리고 55 Pa 이상인 과압 영역을 구분하였으며, 저압 영역에서는 부속실, 차압조절 영역에서는 부속실과 댐퍼 그리고 과압 영역 에서는 댐퍼의 누설면적이 차압 형성에 중요한 관계를 갖고 있는 것을 확인하였다.
Abstract
This study is experimentally analyzed to extract the major parameters affecting the performance of the smoke-control system and the relations of pressure difference between vestibule and supply air pressure zone effect of supply mass flow rate and leakage area in the smoke-control zone. To obtain this, the mock-up building of three-story scale with a total of 10 compartments was constructed, and several apparatus were also installed for in-situ measurement of the ventilation flow rate, pressure difference between compartments, smoke defensive air velocity, the opening-closing force of door, etc. This article show that pressure difference in the smoke-control zone is significantly related with leakage area of vestibule in low pressure region, leakage area of supply air pressure in over pressure region and both of them in pressure control region when the pressure control range of damper is 45 Pa~55 Pa.
Key Words: Smoke-control zone, Vestibule, Supply air zone, Effective leakage area, Opening area
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 2 Crossref
  •    
  • 1,243 View
  • 20 Download
Related articles in Fire Sci. Eng.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next