Fire Science and Engineering 2014;28(4):44-49.
DOI: https://doi.org/10.7731/KIFSE.2014.28.4.044    Published online August 31, 2014.
Propionic acid와 3-Hexanone 계의 최소자연발화온도의 측정
하동명
세명대학교 보건안전공학과
Measurement of Autoignition Temperature of Propionic Acid and 3-Hexanone System
Ha Dong-Myeong
Dept. of Occupational Health and Safety Engineering, Semyung University
요약
혼합물의 최소자연발화온도는 가연성액체의 안전한 취급을 위해서 중요한 지표가 된다. 본 연구에서는 ASTM E659 장치를 이용하여 가연성 혼합물인 Propionic acid와 3-Hexanone 계의 최소자연발화온도와 발화지연시간을 측정하였다. 2성분계를 구성하는 순수물질인 Propionic acid와 3-Hexanone 계의 최소자연발화온도는 각 각 $511^{circ}C$와 $425^{circ}C$로 측정되었다. 그리고 측정된 Propionic acid와 3-Hexanone 혼합물의 최소자연발화온도 실험값은 제시된 식에 의한 예측값과 적은 평균절대오차에서 일치하였다. 그리고 Propionic acid와 3-Hexanone 계는 일부 혼합 조성에서 두 개의 순수물질 가운데 작은 AIT 보다 낮게 측정된 AIT를 보이는 최소자연발화온도거동(Minimum Autoignition Temperature Behavior, MAITB)을 보이고 있다.
Abstract
The autoignition temperaturs (AIT) of solvent mixture is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AIT and ignition delay time for Propionic acid and 3-Hexanone system by using ASTM E659 apparatus. The AITs of Propionic acid and 3-Hexanone which constituted binary system were $511^{circ}C$ and $425^{circ}C$, respectively. The experimental AIT of Propionic acid and 3-Hexanone system were a good agreement with the calculated AIT by the proposed equations with a few average absolute deviation (A.A.D.). And Propionic acid and 3-Hexanone system was shown the minimum autoignition temperature behavior (MAITB).
Key Words: Solvent mixture, Autoignition temperature (AIT), ASTM E659, Propionic acid and 3-hexanone system, Minimum autoignition temperature behavior (MAITB)


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next