Fire Sci. Eng. Search

CLOSE


Fire Sci. Eng. > Volume 30(2); 2016 > Article
Fire Science and Engineering 2016;30(2):27-34.
DOI: https://doi.org/10.7731/KIFSE.2016.30.2.027    Published online April 30, 2016.
광섬유선형감지기를 이용한 화재감지 신호처리방법 및 광신호처리 시험모듈 개발에 관한 연구
김시국, 이영신, 김동은, 임우섭, 이춘하
1호서대학교 소방방재학과
2호서대학교 소방방재학과
3(주)태산전자
4한국소방산업기술원
5호서대학교 소방방재학과
Fire Detection Signal Processing Method Using an Optical Fiber Linear Detector and the Development of an Optical Signal Processing Test Module
Kim Si-Kuk, Lee Young-Sin, Kim Dong-Eun, Lim Woo-Sub, Lee Chun-Ha
1Dept. of Fire and Disaster Protection Engineering, Hoseo Univ.
2Dept. of Fire and Disaster Protection Engineering, Hoseo Univ.
3Tae San Electronics Co., Ltd.
4Korea Fire Institute
5Dept. of Fire and Disaster Protection Engineering, Hoseo Univ.
요약
본 논문은 화재위험성이 높은 터널 및 지하공동구 등 열악한 환경조건에서도 가장 적응성 있는 화재감지로 화재피해를 최소화 할 수 있는 광섬유선형감지기를 이용한 화재감지시스템에 관한 연구이다. 한가닥의 광섬유를 이용하여 m 단위의 온도표시 및 수 km 이상의 장거리 화재감시가 가능하고, 고신뢰성 및 장수명 등 다양한 장점으로 인해 국외의 경우 열악한 장소에 대부분 채용하고 있는 시스템이다. 이로 인해 국내에서도 향후 그 수요가 크게 증가될 것으로 예상된다. 하지만, 현재까지 광섬유선형감지기를 제외한 광신호 구동 및 분석 모듈은 100% 수입에 의존하고 있는 실정이다. 이에 본 연구에서는 현재 수입의 의존도를 줄이고자 광섬유선형감지기를 이용한 화재감지시스템의 국산화 기술개발을 위해 1차적으로 위치 및 온도 측정의 신호처리 방법을 도출하고, 신호처리 검증을 위해 광신호처리 시험모듈을 설계 제작하여 그 성능을 확인하였다.
Abstract
This paper studies a fire detection system using an optical fiber linear detector which can minimize damage from a fire by the most adaptable even in poor environmental conditions such as a tunnel or utility-pipe conduit vulnerable to fire. Using a strand of optical fiber, temperature can be displayed in intervals of meters and a fire can be detected remotely from a distance of several kilometers. Thanks to its strengths such as high reliability and long life, it is widely applied in harsh environments in the overseas. Therefore demands are expected to grow greatly in Korea as well. However, all optical signal drive and analysis module except for the optical fiber linear detector, tend to rely on import. Firstly this study deduced the location and the method of processing signals measuring temperature by using the optical fiber linear detector in order to develop a technology for a domestic model of fire detection system. Secondly this study designed and manufactured the optical analysis test module, and then we checked its performance.
Key Words: Optical fiber linear detector, Location measurement, Temperature measurement, Signal processing method, Optical signal processing test module
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 1,280 View
  • 12 Download
Related articles in Fire Sci. Eng.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer