Fire Science and Engineering 2018;32(6):84-90.
DOI: https://doi.org/10.7731/KIFSE.2018.32.6.084    Published online December 31, 2018.
양자전이 비행시간 질량분석기를 이용한 화학물질 화재 발생 시 대기질 조사 연구
김소영, 조동호, 박정민
1한강유역환경청 시흥화학재난합동방재센터
2한강유역환경청 시흥화학재난합동방재센터
3국립환경과학원 기후대기연구부
Study on Air Quality in the Case of Chemical Fires Using Proton Transfer Reaction-Time of Flight Mass Spectrometer
Kim So-Young, Cho Dong-Ho, Park Jungmin
1Ministry of Environment Han River Basin Environment Office, Siheung Joint Inter-agency Chemical Emergency Preparedness Center
2Ministry of Environment Han River Basin Environment Office, Siheung Joint Inter-agency Chemical Emergency Preparedness Center
3National Institute of Environmental Research, Air Quality Research Division
요약
화학사고는 폭발, 누출 유출, 화재 등 다양한 형태로 발생한다. 특히 화재로 인한 화학사고는 매연으로 인해 주변 대기환경에 심각한 영향을 주며 주민의 불안을 야기하여 신속한 원인 물질 파악과 주변 지역 대기질 영향조사가 중요하다. 본 논문에서는 화재 시 원인물질을 파악하고 대기질을 실시간 모니터링 하기 위해 양자전이 비행시간 질량분석기를 사용하였다. 이 분석기는 시료채취와 전처리 없이 빠른 응답시간을 가져 실시간 분석이 가능하며 또한 수소친화도가 높은 대부분의 휘발성유기화합물질의 정량 정성 분석이 가능하여 화재 원인 물질을 밝히고 주변 대기의 영향을 조사하는데 적합하다. 실제로 2018년 4월에 ${igcirc}{igcirc}$ 지역 화재 발생 시 양자전이비행시간질량분석기를 이용하여 측정한 결과 메탄올, 아세톤, 메틸에틸케톤이 주요 원인 물질임을 알 수 있었다.
Abstract
Chemical accidents occur in various forms, such as explosions, leaks, spills, and fires. In particular, chemical accidents caused by fires seriously affect the surrounding air environment due to soot, causing anxiety to the residents. Therefore, it is important to identify the causative substances quickly and examine the influence of air quality in the surrounding area. In this paper, proton transfer reaction-time of flight mass spectrometry(PTR-ToFMS) was used to identify the causative material in a fire and monitor the air quality in real time. This analyzer is capable of real-time analysis with a rapid response time without sample collection and pretreatment. In addition, it is suitable for quantitative and qualitative analysis of most volatile organic compounds with high hydrogen affinity, to identify the cause of fire and examine the influence of ambient air. In April 2018, when a local fire occurred, methanol, acetone, and methyl ethyl ketone were the main causative agents in PTR-ToFMS.
Key Words: Fire, Chemical accidents, Proton Transfer Reaction-Time of Flight Mass Spectrometer (PTR-ToFMS)


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next