Fire Science and Engineering 2019;33(3):121-127.
DOI: https://doi.org/10.7731/KIFSE.2019.33.3.121    Published online June 30, 2019.
동일한 제조사의 ABS 모듈 결함으로 인한 차량화재 사고사례 분석
박남규1, 이동규2, 조영진3, 문병선3, 송재용3
1국립과학수사연구원 법공학부장
2국립과학수사연구원 연구사
3국립과학수사연구원 연구관
Analysis on the Fire Accidents Vehicles Caused by Faults in the Same Anti-lock Brake System (ABS) of the same Manufacturer
Nam-Kyu Park1, Dong-Kyu Lee2, Young-Jin Cho3, Byung-Sun Moon3, Jae-Yong Song3
1Head, Dept. Forensic Engineering, National Forensic Service
2Researcher, National Forensic Service
3Senior Researcher, National Forensic Service
Correspondence:  Nam-Kyu Park, Tel: +82-33-902-5500, Fax: +82-33-902-5907, 
Email: ok825@korea.kr
Received: 29 January 2019   • Revised: 5 April 2019   • Accepted: 5 April 2019
요약
본 논문에서는 자동차 ABS 모듈의 결함으로 인한 화재사고에 대하여 기술하였다. 최근 발생한 화재 사례 중 동일 제조사의 ABS 모듈을 적용하는 다수의 차량에서 유사한 결함으로 인해 화재가 발생하는 경향을 나타내었다. 앞서 언급한 ABS 모듈에서는 배터리를 통해 상시전원으로 공급되는 전원배선 사이에서 절연파괴가 발생되는 특징을 나타내는데 이러한 부분은 연소 확대 과정에서 외부 화염에 의해 형성되기 어려운 부분으로 ABS 모듈 자체의 결함으로 판단된다. 본 연구의 결과로 부터 특정 제조사에서 생산 판매되는 차량에 대한 화재원인 조사에 있어서는 반드시 ABS 모듈의 결함 여부에 대한 조사가 필수적으로 진행되어야 할 것이다.
Abstract
This study examined a fire accident caused by a defect in the vehicle ABS module. A large number of vehicles using the same manufacturer's ABS module in recent fire events showed a tendency to combust due to the same faults. As previously stated in the ABS module which shows the electrical breakdown between the power lines supplied to the constant power source by the battery. The electrical breakdown of the ABS module was caused by defects of the ABS module itself that were influenced by of the external flame. These results highlight the need to determine if there is a deficiency of the ABS module in the investigation of the cause of a fire in a vehicle which is produced by the same manufacturer.
Key Words: Vehicle fire, Anti-lock brake system, Fire investigation, Electrical breakdown
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1 Crossref
  •    
  • 1,426 View
  • 39 Download
Related articles in Fire Sci. Eng.


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next