1. H. W. Seo, J. W. Shon, D. H. Kim, S. H. Hong, S. B. Lee and S. B. Lim, “Levels of Effectiveness of Water Curtain Equipment Applied When Mitigating Fire Compartment Installation of Logistics Facilities”, Journal of the Korean Society of Hazard Mitigation, Vol. 24, No. No. 5, pp. 157-163 (2024),
https://doi.org/10.9798/KOSHAM.2024.24.5.157.
2. S. C. Lee, B. J. Kim, J. O. Lee, C. H. Park and C. H. Hwang, “An Experimental Study on the Effects of the Shape of a Drencher Head on the Characteristics of a Water Curtain”, Fire Science and Engineering, Vol. 30, No. No. 3, pp. 86-93 (2016),
https://doi.org/10.7731/KIFSE.2016.30.3.086.
3. J. H. Choi, S. H. Choi, K. S. Cho and S. U. Chae, “An Experimental Study for the Fire Performance of EIFS with a Drencher System”, Journal of the Korean Society of Hazard Mitigation, Vol. 20, No. No. 3, pp. 123-130 (2020),
https://doi.org/10.9798/KOSHAM.2020.20.3.123.
4. J. G. Jo and C. Y. Lee, “Experimental Study on Thermal Radiation Attenuation Using Water Mist of Twin-Fluid Atomizer”, Fire Science and Engineering, Vol. 35, No. No. 4, pp. 24-32 (2021),
https://doi.org/10.7731/KIFSE.67a3ae31.
5. G. H. Ko, “Numerical Study on Heat Radiation Attenuation and Flow Characteristics by Water Mist Curtains”, Fire Science and Engineering, Vol. 36, No. No. 4, pp. 1-7 (2022),
https://doi.org/10.7731/KIFSE.b677f696.
6. Y. Chen, J. Jia, G. Che, Z. Zhu and Z. Shen and Y. Wu, “Study on Smoke Blocking and Thermal Radiation Attenuation by Water Curtain in Tunnel Fire”, Scientific Reports, Vol. 13, No. 237, (2023),
https://doi.org/10.1038/s41598-023-27437-2.
7. L. Zhou, X. Shi, H. Jiang, Z. Xu, S. Li and W. Xu, “An Experimental Study on the Thermal Radiation Attenuation Effect of Water Mist from Flat Fan Nozzle”, Thermal Science and Engineering Progress, Vol. 39, pp. 101634(2023),
https://doi.org/10.1016/j.tsep.2022.101634.
8. H. T. Khoat, J. T. Kim, T. D. Quoc, J. H. Kwark and H. S. Ryou, “A Numerical Analysis of the Fire Characteristics after Sprinkler Activation in the Compartment Fire”, Energies, Vol. 13, No. 12, pp. 3099(2020),
https://doi.org/10.3390/en13123099.
9. M. Turco, P. Lhotsky and G. Hadjisophocleous, “Investigation into the Use of a Water Curtain over Openings to Prevent Fire Spread”, MATEC Web of Conferences, Vol. 46, pp. 04001(2016),
https://doi.org/10.1051/matecconf/20164604001.
10. C. Meraner, E. S. Skilbred and K. S. Arsava, “Experimental Investigation of Water-Based Fire Suppression Systems on External Façade Fires”, Fire Technology, Vol. 60, pp. 3629-3648 (2024),
https://doi.org/10.1007/s10694-024-01595-9.
11. ISO 9705-1, “2016 Reaction to Fire Tests-Room Corner Test for Wall and Ceiling Lining Products-Part 1: Test Method for a Small Room Configuration”, (2016).
12. C. H. Hwang, A. Lock, M. Bundy, E. Johnsson and G. H. Ko, “Studies on Fire Characteristics in Over- and Underventilated Full-Scale Compartments”, Journal of Fire Sciences, Vol. 28, No. No. 5, pp. 459-489 (2010),
https://doi.org/10.1177/0734904110363106.
13. A. Lock, M. Bundy, E. L. Johnsson, A. Hamins, G. H. Ko, C. H. Hwang, P. Fuss and R. Harris, “Experimental Study of the Effects of Fuel Type”, Fuel Distribution, and Vent Size on Full-Scale Underventilated Compartment Fires in an ISO 9705 Room”, NIST Technical Note 1603, National Institute of Standards and Technology, Gaithersburg, MD, USA, (2008).
15. H. S. Yun, S. Y. Mun and C. H. Hwang, “The Sinkhole Phenomenon—Changes in Compartment Fire Characteristics Due to Incomplete Combustion before Flame Ejection”, Applied Sciences, Vol. 12, No. No. 23, pp. 12278(2022),
https://doi.org/10.3390/app122312278.
16. V. Babrauskas and S. J. Grayson, “Heat Release in Fires”, Elsevier Science Publishers Ltd, London, UK (1992).
17. ISO 834-1, 1999 Fire-Resistance Tests-Elements of Building Construction-Part 1: General Requirements, (1999).
18. H. S. Yun, S. Y. Mun and C. H. Hwang, “An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions”, Fire Science and Engineering, Vol. 29, No. No. 5, pp. 34-41 (2015),
https://doi.org/10.7731/KIFSE.2015.29.5.034.
19. H. S. Han, H. S. Yun and C. H. Hwang, “Calibration of the Plate Thermometer for Measuring Heat Flux Using a Conical Heater”, Journal of Mechanical Science and Technology, Vol. 33, pp. 3563-3569 (2019),
https://doi.org/10.1007/s12206-019-0650-1.