Journal of Korean Institute of Fire Science and Engineering 2009;23(5):161-166.
Published online October 31, 2009.
개방식 장치를 이용한 tert-Pentanol + Propionic Acid 및 p-Xylene + Propionic Acid 계의 하부인화점 측정 및 예측
하동명, 이성진
1세명대학교 보건안전공학과2세명대학교 임상병리학과
The Measurement and Estimation of the Lower Flash Points for tert-Pentanol + Propionic Acid and p-Xylene + Propionic Acid Systems Using Open-Cup Apparatus
Ha Dong-Myeong, Lee Sung-Jin
요약
본 연구에서는 tert-pentanol + propionic acid 및 p-xylene + propionic acid계의 하부인화점을 Tag 개방식장치(ASTM D1310-86)를 이용하여 측정하였다. 실험값은 Raoult의 법칙, van Laar 모델식과 NRTL 모델식에 의해 계산된 값들과 비교 되었다. 그 결과, van Laar 모델식과 NRTL 모델식에 의한 예측값이 Rauolt의 법칙에 의한 예측값 보다 실험값에 더욱 근접하였다. 이는 tert-pentanol + propionic acid 및 pxylene + propionic acid계와 같은 비이상 용액의 활동도 계수값을, van Laar 및 NRTL 모델식이 Raoult의 법칙보다 정확하게 계산하기 때문이다. 또한, NRTL 모델식의 실험값에 대한 모사성이 van Laar 모델식의 그것 보다 우수하였다.
Abstract
The lower flash points for the tert-pentanol + propionic acid and p-xylene + propionic acid systems were measured by Tag open-cup apparatus. The experimental data were compared with the values calculated by the Raoult's law, the van Laar equation and the NRTL equation. The calculated values based on the van Laar and NRTL equations were found to be better than those based on the Raoult's law. It was concluded that the van Laar and NRTL equations were more effective than the Raoult' law at describing the activity coefficients for non-ideal solution such as the tert-pentanol + propionic acid and p-xylene + propionic acid systems. The predictive curve of the flash point prediction model based on the NRTL equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the van Laar equation.
Key Words: Flash point, Tag open-cup apparatus, tert-Pentanol + propionic acid, van Laar equation, NRTL equation


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next